Walk-in test chambers
Producent | |
---|---|
Grupa urządzeń | |
Zastosowanie |
Temperature/humidity type “walk-in” chambers are used for environmental test of very large objects for example complete products.
Features
Features:
- Available versions: temperature only or temperature/humidity control,
- Internal volume from 4 to 53 m3,
- Temperature control range from -40, -30 or -10 °C to +80 °C,
- Temperature fluctuation: +/- 0,5 °K,
- Temperature variation in space: 2,5 °K,
- Humidity control range from 10 to 95 %RH,
- Humidity fluctuation: +/- 4 %RH,
- Humidity variation in space: 8 %RH,
- High-power N-instrumentation with 10.4-inch color touch panel for superior operability,
- Possibility monitoring and full controlling the chamber via network connection.
Included equipment:
- Test chamber made from stainless steel, housing made from stainless steel covered by PVC,
- Isolation from hard polyurethane foam 64 mm,
- Single opening door 850 x 1800 mm with window 189×289 mm,
- Internal lighting,
- Air exchange port for ambient air,,
- Cable port in side wall, diameter 50 mm,
- Water-cooled or air-cooled refrigeration system.
Options
Some of possible options:
- Changement of requirements acording to the customer requests,
- Increasing of chamber floor loading,
- Wiewing window in side wall,
- Air cooled refrigeration unit,
- Additional cable ports 50, 100 or 150 mm,
- Door curtain or entrance gate,
- Decreasing of air velocity in test area,
- Additional measuring sensors,
- Temperature and Humidity recorders,
- Communication interfaces and controlling by an external PC.
ESPEC company can also addapt the chamber to the specific requirements of the customer.
TYPES AND VOLUMES
Climatic test chambers | ||
---|---|---|
Type | Temperature range | Humidity range |
EBE | -40 do +80 °C | 10 do 95 %RH |
EBL | -30 do +80 °C | 10 do 95 %RH |
EBR | -10 do +80 °C | 10 do 95 %RH |
Temperature test range | ||
Type | Temperature range | Humidity range |
EBF | -40 do +80 °C | — |
EBU | -30 do +80 °C | — |
EBUU | -10 do +80 °C | — |
Size | Capacity of the test area [m3] | Surface ot the floor of the test area [m2] |
Internal dimensions
S x W x G [mm] |
External dimensions
S x W x G [mm] |
---|---|---|---|---|
1 | 4.2 | 2.0 | 1020 x 2100 x 1970 | 1790 x 2305 x 2100 |
2 | 8.1 | 3.9 | 1970 x 2100 x 1970 | 2740 x 2305 x 2100 |
3 | 12.5 | 5.9 | 3020 x 2100 x 1970 | 3790 x 2305 x 2100 |
4 | 16.8 | 8.0 | 4070 x 2100 x 1970 | 4840 x 2305 x 2100 |
6 | 25.8 | 12.3 | 4070 x 2100 x 3020 | 5295 x 2405 x 3150 |
8 | 34.8 | 16.6 | 4070 x 2100 x 4070 | 5295 x 2405 x 4200 |
10 | 43.8 | 20.8 | 5120 x 2100 x 4070 | 6345 x 2405 x 4200 |
12 | 52.7 | 25.1 | 6170 x 2100 x 4070 | 7395 x 2405 x 4200 |